Vaporised hydrogen peroxide that stays gaseous throughout the cycle, reaches the places aerosol methods cannot, and leaves zero residue — so the space is back in use the moment ppm returns to zero.
Safe, controlled transfer of materials between classified areas while minimising the risk of cross-contamination. A patented VHP generator delivers superior vapour distribution and a uniform kill across the load, decontaminating the surface of everything that passes through — including heat-sensitive materials that cannot go through an autoclave.
VHP Pass BoxVHP pass boxes move material between classified areas without opening a door between them, using vaporised hydrogen peroxide to decontaminate the surface of everything that passes through. Which one you need depends on whether the two areas share a cleanliness classification.
For material transfer between areas of the same or similar cleanliness classification. It provides a controlled chamber for VHP decontamination before material moves into the receiving area.
Combines VHP decontamination with controlled airflow for an additional level of contamination control when transferring between areas of different cleanliness classifications.
The chamber holds a controlled airflow environment and incorporates filtration, so the risk of contamination during transfer is minimised rather than merely contained.
It gives you a controlled and validated route for material transfer, reducing the risk of introducing viable and non-viable contamination into critical areas. Static or Dynamic is selected on facility layout, cleanliness classification, airflow requirements and the process itself — tell us those four and we will specify it.
Choose a single-door chamber where material enters and leaves the same side, or a pass-through where the load moves between two classified areas without breaking the barrier.
Load and unload from one face. Suits standalone sterilization of heat-sensitive materials where the room classification does not change.
Doors on both faces with interlocking, moving material from a lower classification into a higher one with surface decontamination in between.
From a single piece of equipment or a small chamber through to entire facilities, using the Cleamix Oy (Finland) system. Arranged as contamination response or as preventive control, in line with your environmental monitoring data, scheduled maintenance and shutdown periods.
Cleamix VCS on siteWritten feedback from research institutes, universities, hospitals and diagnostic centres following vH2O2 bio-decontamination carried out by our team. Tap any letter to read it in full.
Personal email addresses and direct phone numbers have been redacted from these documents. Originals are available on request.
The bio-decontamination chamber is designed, manufactured and tested against the following. Complete IQ/OQ testing is carried out at the factory test area before shipment.
Hydrogen peroxide vapour is hazardous during a cycle. Systems are supplied with interlocks, ppm monitoring and remote control so the operator stays outside the treated space until the reading returns to a safe level.
Chamber size, material type, room classification and cycle frequency are what we need to scope a VHP system or a decontamination contract. Send those and we will come back with a specification and a price.